Standard Features
The ECOM VETS package includes:
19’ Rack style Analyzer with up to 6 gas sensors for measurement of O2, CO (2 ranges), NO, NO2, SO2, Combustibles
Gas & Air, & Sensor Temperature, and Draft / Pressure Heated Flame Ionization Detector for Hydrocarbons (ppm)
Optional Opacity Meter, with RPM
Oil Temperature, and Ambient Conditions sensor
Optional Heavy duty cabinet, with dedicated PC, slide out drawer keyboard / mouse
Heated Sample Line
Optional Thermo-electric gas cooler & moisture trap with automatic moisture dump
On-board flowmeter
In-line particulate filter
CO2, Efficiency, Losses, Excess Air, & Oxygen correction calculations
Automatic CO Over-range protection
Spare consumables (filters, printer paper, smoke test disks, etc.)
VETS Software package
Operation Manual
|
VETS consists of an exhaust gas analyzer, an opacity meter (SAE J1667 compliant), a Hydrocarbon analyzer (HFID), and a dedicated computer system, all housed in a portable industrial shop cabinet. Measured parameters include O2, CO, CO2, NOx, Hydrocarbons, Smoke Opacity, Exhaust Temperatures, RPM, and Oil Temperature. The VETS software manages a fleet database and includes every possible identification record, such as vehicle ID, engine type, mileage, shop location, catalytic converter type, etc. Real time gas readings are displayed on the PC, and with a simple click of the mouse, gas and smoke measurements are performed and recorded with test results displayed instantaneously. The VETS software practically automates the emission testing procedure and maintains a historical database for every vehicle in the fleet. VETS system was developed from years of experience using diesel engine emission monitoring as diagnostic tool. This concept, widely used in the underground mining industry, has become known as Emissions Based Maintenance. When combined with a comprehensive maintenance program, companies have achieved reductions of up to 65% on CO and 55% on DPM, without the expense of alternative fuels and after-treatment devices. In addition, a 3% to 5% savings in fuel consumption has been realized, translating to a significant impact on the bottom line. VETS has also been a critical tool for developers of emission control products, capable of providing extensive & reliable emissions data in an easy to use and affordable package.
TECHNICAL SPECS
| PARAMETER |
RANGE |
ACCURACY |
RESOLUTION |
|
|
| Oxygen |
0-21% |
± 0.1% of Reading |
0.1% vol. |
|
|
| Carbon Monoxide |
0-4,000/40,000 ppm |
± 2% of Reading |
1 ppm |
|
|
| Nitric Oxide |
0-4,000 ppm |
± 2% of Reading |
1 ppm |
|
|
| Nitrogen Dioxide |
0-500 ppm |
± 2% of Reading |
1 ppm |
|
|
| NOx (NO + NO2) |
0-4,500 ppm |
± 2% of Reading |
1 ppm |
|
|
| CO2 (calculated) |
0.0%- Fuel Max% |
|
0.1% |
|
|
| Hydrocarbons* (HFID) |
0-10/100/1,000/10k ppm |
± 2% of Reading |
0.1 ppm |
|
|
| Opacity (optional) |
0-100% |
± 2% of Reading |
0.1% |
|
|
| Oil Temperature |
32-250º F |
± 3% of Reading |
1 degree |
|
|
| RPM- Engine Speed |
0-10,000 |
± 3% of Reading |
1RPM |
|
|
| Exhaust Tempereature |
32-1,800º F |
± 3% of Reading |
1 degree |
|
|
| Exhaust Backpressure |
± 40" H2O |
± 3% of Reading |
0.1% H2O |
|
|
| |
|
|
|
|
|
| *Hydrocarbons measurement by Heated Flame Ionization Detector |
| |
|