ECOM America, Ltd.
1628 Oakbrook Drive
Gainesville, GA 30507

Toll Free 877.326.6411
TEL. 770.532.3280
FAX 770.532.3620

 


ECOM SEEA

INHERENTLY INTELLIGENT

BROCHURE

+ + + +

Standard Features

The ECOM SEEA package includes:

  • Analyzer with up to 5 gas sensors for measurement of O2, CO (2 ranges), NO, NO2, SO2, Combustibles,
  • Gas & Air, & Sensor
  • Temperature, and Draft / Pressure Internal Pump
  • SS Sample inlets
  • Heated Sample Line
  • Optional Thermo-electric gas cooler & moisture trap with automatic moisture dump
  • On-board flowmeter
  • In-line particulate filter
  • CO2, Efficiency, Losses, Excess Air, & Oxygen correction calculations
  • Automatic CO Over-range protection
  • Internal battery
  • Spare consumables (filters, printer paper, smoke test disks, etc.)
  • SEEA Programming software
  • Operation Manual
  • NEMA 12 steel enclosure
  • Click to view the Full Size application.ECOM’s Stationary Equipment Emission Analyzer (SEEA) is our newest and most inherently intelligent emission measuring system to date. Based on the ETV Performance Verified A-PLUS, the SEEA bolts to the wall of your boiler or engine room and serves up to 4 separate exhaust stacks. Designed to measure O2, CO and NOx, the SEEA can run sampling cycles at virtually any frequency and duty cycle, and can be configured to monitor from 1 to 4 emission sources. The complete system is housed in a NEMA 12 steel enclosure with 1/4” bulkhead fittings for all process connections. Utilizing extremely flexible interactive intelligence software, the SEEA system is capable of a wide array of tasks to including remote monitoring, emissions recording, and even enhanced control of SCR systems through a NOx current feedback loop or MODBUS port. The SEEA also features multiple alert modes to indicate combustion system malfunctions. Monitored test data is collected in a simple spreadsheet format including time, date, raw emissions data, and calculated values such as O2 correction. All emissions test data is accessible directly through local USB port, 4-20mA output contacts or local MODBUS port. While designed for installation in stationary locations, the SEEA system can be configured for mobile applications, such as marine vessels and railroad locomotives. Dedicated emission measurement of stationary combustion systems has never been easier or more affordable. You can always see how your machinery is performing with a SEEA from ECOM. Reach out to ECOM, the global leader in portable, and now, stationary emission analyzers.

    • TECHNICAL SPECS
    • PARTS
    • close tabs
    MEASUREMENT (KEY) RANGE ACCURACY** RESOLUTION    
    Oxygen (O) 0-21% ± 2% Reading 0.1% vol.    
    Carbon Monoxide (C) 0-4,000 ppm ± 2% Reading 1 ppm    
    Carbon Monoxide (V) 0-40,000 ppm ± 2% Reading 1 ppm    
    Standard NOx Ranges          
    Nitric Oxide (N) 0-4,000 ppm ± 2% Reading 1 ppm    
    Nitric Oxide (X) 0-500 ppm ± 2% Reading 1 ppm    
    LOW NOx Ranges          
    Nitric Oxide (.N) 0-300.0 ppm ± 2% Reading 0.1 ppm    
    Nitric Dioxide (.X) 0-50.0 ppm ± 2% Reading 0.1 ppm    
    Sulfur Dioxide (S) (optional) 0-5000 ppm ± 2% Reading 1 ppm    
    Calculated Parameters          
    Carbon Dioxide (CO2) 0-20% ± 3% Reading 0.1%      
    O2 Correction 0-920%        
               
               
    ** ACCURACY: When calibrated prior to use per ECOM America, Ltd. specifications.
     
    PHYSICAL Enclosure Type: Wall Mount NEMA 12
    Instrument: 20” x 20" x 10”
    Sample Inlet(s): One 1/4" tubing connection for each sample inlet. Maximum of 4 per unit. Flow Rate of sample = 2.5 liters per minute.
    Weight: 100 lb.
    Condensate Drain: One 1/4" tubing connection located at the bottom of the enclosure
    Enclosure Vent: Enclosure gas discharge (3" PVC Pipe Fitting) to be routed to outside air.
    Power: 120VAC 60Hz, 200W max. Analyzer contains 12V sealed lead acid battery.
    Communications: USB (local) up to 15 feet. Output Options: 4-20mA outputs, RS232/RS485, or MODBUS.
     
    ELECTRICAL Electrical Connection: A dedicated junction box with conduit knockouts and customer connection terminal strip is provided at the bottom of the analyzer enclosure.
     
    OPERATING TEMPERATURE 65°F - 95°F, 20% - 90% Non-Condensing
     
               
     
               
    ECOM SEEA Description ECOM Part#
    Configuration Options    
    ECOM AC O2, CO, NO, NO2  
    O2, CO, LOW NOX  
    O2, CO (low), CO (high), NO, NO2  
    O2, CO, NO, NO2, SO2  
         
    Accessories & Options    
      Heated Line w/ Probe Assembly (xx designates feet, i.e. a 30ft line will be p/n PRT79525-30) - priced per foot PR 79525-XX
      Additional Sample Inlet Valves -per each SEEA VALVE
      Analog (4-20 mA) or MODBUS outputs for up to 8 channels SEEA COMM
      Valve replacement tubing TB250X375SI1P
       NOx / SO2 Filter media (1 lb)  NOXSOX 79275
       Particulate Filters (package of 10)  FILTER75316
    SPARE PARTS    
      T-GAS dummy Thermocouple CONNECTOR70280
      Draft Connector Fitting (3 notch) CONNECTOR71301
       Gas Connector Fitting (2 notch) 8mm  CONNECTOR71302
      O-ring for Draft Inlet (1.75x4) 7mm ORING71308
      O-ring for Gas Inlet (1.75x5)  ORING71309
      Water Trap Bowl  RBR 75325
      NOx / SOx Bead Tube  RBR 71286
      SEEA Battery 12V 3.3 AH  PRT 79287
      Internal Pump  PRT 79295
    SENSORS    
      Oxygen (O2)  RBR 75299
    Sensor Options & Ranges: O2 (0.00 -21.0%), CO low (0-4,000 ppm), CO high (0-40,000 ppm), NO (0-4,000 ppm), NO2 (0-500 ppm), LOW NOX (0-400 ppm NO & 0-100 ppm NO2), SO2 (0-5,000 ppm), Combustibles (0-6.00%)
     Carbon Monoxide (low CO)  RBR 75292
     Sulfur Dioxide (SO2)  RBR75301
     Nitric Oxide (NO)  RBR75298
     Nitrogen Dioxide (NO2)  RBR 75296
    Carbon Monoxide (high CO)  RBR 75293
       Combustible  RBR 75313
    NOTES:
    Please note: The combustible sensor, either Catalytic Pellistor or Infrared type must be serviced by ECOM factory personnel.