With wireless remote control, the J2KN’s handheld remote allows complete operation of the analyzer showing all values at a glance, zoom display capability, and plug-in memory up to 256 MB. The tactile keypad guides the operator through the various functions of the analyzer. The remote display feature makes the J2KN an ideal emission analyzer where combustion controls are located away from the flue test port on large combustion systems. The J2KN can be fitted with up to 5 gas sensors to measure O2, CO, NO, NO2, SO2, and Combustibles, along with gas and ambient temperatures, stack draft & pressure, plus calculations of CO2, efficiency, excess air, and oxygen correction to 20%. Standard J2KN features include high flow pump with flowmeter, integral impact printer, and thermo-electric gas cooler with automatic condensate drain. Consistent flow and pressure of the gas sample assures accuracy of the gas measurement, evidenced by the in-line flowmeter, which allows the operator to monitor gas flow at all times. An on-board impact printer provides instantaneous print-out of all measured & calculated parameters. The J2K also features a SMOKE test function, handy for checking the integrity of Diesel Particulate Filters. An Automatic and Manual CO bypass function protects the CO sensor from over exposure. Sensor life generally averages 2-3 years due to proprietary design of sensor manifold and gas delivery system. Along with superior performance features, the J2KN also offers wireless transmission of real time data via remote receiver connected to your laptop PC using ECOM’s Advanced DAS & VETS software programs. Complete emission reports are transmitted and stored to your laptop while on-site. The J2KN is a compliance level analyzer, meeting all current state & federal protocols for periodic monitoring. ECOM offers custom length heated sample lines, if required for your applications.
- TECHNICAL SPECS
- PARTS
- close tabs
| MEASUREMENT (KEY) |
RANGE |
ACCURACY |
RESOLUTION |
SENSOR LIFE |
SENSOR TYPE |
| Oxygen (O) |
0-21% |
± 2% Measured |
0.1% vol. |
2 Years |
Electrochemical |
| Carbon Monoxide (C) |
0-4,000 ppm |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
| Carbon Monoxide (V) |
0-40,000 ppm |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
| Nitric Oxide (N) |
0-4,000 ppm |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
| Nitric Oxide (.N) |
0-400 ppm |
± 2% Measured |
0.1 ppm |
3 Years |
Electrochemical |
| Nitrogen Dioxide (X) |
0-500 ppm |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
| Nitrogen Dioxide (.X) |
0-50 ppm |
± 2% Measured |
0.1 ppm |
3 Years |
Electrochemical |
| Sulfur Dioxide (S) |
0-5,000 |
± 2% Measured |
1 ppm |
3 Years |
Electrochemical |
| Combustibles (H) |
0-6.00% |
± 2% Measured |
0.01% |
5years |
Peellister |
| Gas Temperature |
32-1800 F |
± 2% Measured |
1 deg F |
10 Years |
NiCrNi |
| Ambient Temperature |
0-250 F |
± 2% Measured |
1 deg F |
10 Years |
Semi-Conductor |
| Draft / Pressure |
± 40" H2o |
± 2% Measured |
0.1% H2O |
10 Years |
DMS |
| O2 Correction |
0-20% Oxygen |
|
|
|
|
| Smoke Scale |
0-9 |
|
|
|
| Carbon Dioxide (CO2) |
0-CO2 max of fuel |
Calculated |
|
|
|
| Efficiency |
0-99.9% |
Calculated |
|
|
|
| Exxess Air (Lambda) |
1- Infinity |
Calculated |
|
|
|
| |
|
|
|
|
|
| *ACCURACY: When calibrated prior to use per ECOM America, Ltd. specifications. |
| |
| PHYSICAL |
Instrument: 16” x 10” x 12”
Probe: 13” Length x 3/8” OD Inconel w/ Pistol Grip Handle*
Sample Line: 15’ high-temp flex hose w/thermocouple wire*
Weight: 28 lb. |
 |
| |
| ELECTRICAL |
AC: 110/220V 50/60Hz (User selectable)
Batteries: 6-8 hour battery life, 12V lead-acid
Pump: Flow rate of 3.5+ lpm
Display: Backlit, adjustable contrast & zoom, displays all
parameters simultaneously. |
 |
| |
| OPERATING TEMPERATURE |
Core temperature of the instrument is monitored continuously.
Internal Temperature Compensation software assures accurate
sensor response over the range of 20°F to 104°F. |
 |
| |
| |
|
|
|
|
|
| *Optional probe & sample line lengths are available. |
| |
|
|
|
|
|
| ECOM J2KN 2-5 GAS ANALYZER |
DESCRIPTION |
ECOM PART # |
| J2K-N Configurations |
|
|
 |
ECOM J2KN 4 gas analyzer (OCNX) O2, CO (low), NO, NO2 |
RBR 69884 |
| ECOM J2KN 4 gas analyzer (OVNX) O2, CO (high), NO, NO2 |
RBR 69885 |
| ECOM J2KN 4 gas analyzer (OCNX) O2, CO (low), LOW NOX 0.1 ppm resolution on NO, NO2 |
RBR 69886 |
| ECOM J2KN 5 gas analyzer (OCVNX) O2, CO (low), CO (high), NO, NO2 |
RBR 69889 |
| ECOM J2KN 5 gas analyzer (OCNXS) O2, CO (low), NO, NO2, SO2 |
RBR 69887 |
| ECOM J2KN 5 gas analyzer (OVNXS) O2, CO (high), NO, NO2, SO2 |
RBR 69888 |
| ECOM J2KN 5 gas analyzer (OCNXH) O2, CO (low), NO, NO2, COMBUSTIBLES |
RBR69890 |
| ECOM J2KN 5 gas analyzer (OVNXH) O2, CO (high), NO, NO2, COMBUSTIBLES |
RBR69891 |
| Meets requirements for protocol testing/ reporting |
ADVANCED DAS - WIRELESS USB - SOFTWARE - includes ANTENNA, CD-ROM, 15' USB cable, and User Manual. |
PRT90006 |
| |
Heated Line complete w/2.5' Probe, 1/4" compression fittings, LED temperature indicator, and cable hanger loop. Priced per foot. XX denotes length, in feet. |
PRT 79525-XX |
|
Heavy Duty Shipping/Transport Case |
PRT ZRC2624 |
| BTS SOFTWARE |
|
|
| |
J2KN Boiler Test System - Wireless Data Transmission and Boiler Service, Monitoring, &Reporting System |
PRT90007 |
| CONSUMABLES |
|
|
 |
Impact Printer Ribbon |
RBR 69519 |
 |
Printer Paper for Impact Printer (5 rolls) |
PRT 79285 |
 |
Smoke Test Paper (200 disks/bag) |
SOOT 71283 |
 |
Nox /Sox Filter Cartridge |
RBR71292 |
 |
In Line Round Filter |
RBR71185 |
 |
Particulate Filters (package of 10) |
FILTER75316 |
| SPARE PARTS |
|
|
 |
5 foot Pistol Grip Probe (Standard) |
RBR 71270 |
 |
3 foot Pistol Grip Probe (Standard) |
RBR 71271 |
 |
1 foot Pistol Grip Probe (complete) |
RBR 71282 |
 |
1 Foot probe pipe |
RBR 71265 |
 |
Pistol Grip |
RBR 71280 |
 |
Probe Cone |
RBR 71297 |
 |
15 foot Sample Line (Standard) |
RBR71276 |
 |
30 foot Sample Line (Standard) |
RBR71278 |
 |
T-GAS dummy Thermocouple |
CONNECT70280 |
 |
GAS ADAPTER (J2KN) |
ADAPTER71353 |
 |
DRAFT / PRESSURE ADAPTER |
ADAPTER71354 |
 |
O-ring for Draft Inlet (1.75x4) 7mm |
ORING71308 |
 |
O-ring for Gas Inlet (1.75x5) |
ORING71309 |
 |
Probe Calibration Attachment |
PROBE CAL ASSY |
 |
Water Trap Bowl |
RBR 75325 |
 |
Magnetic Holster for Remote |
RBR 75325 |
| SENSORS |
|
|
 |
Oxygen (O2) |
RBR 75299 |
 |
Carbon Monoxide (low CO) |
RBR75292 |
 |
Sulfur Dioxide (SO2) |
RBR75301 |
 |
Nitric Oxide (NO) |
RBR75298 |
 |
Nitrogen Dioxide (NO2) |
RBR75296 |
 |
Carbon Monoxide (high CO) |
RBR75293 |
 |
Combustible |
RBR 75313 |
| NOTES: |
| Please note: The combustible sensor, either Catalytic Pellistor or Infrared type must be serviced by ECOM factory personnel. |
| |
|
|
ECOM J2KN Portable Emission Analyzer
with Wireless Remote Control ECOM J2KN is a uniquely packaged portable emission analyzer and can be fitted with up to 5 gas sensors for O2, CO (low or high range), NO, NO2, and SO2. The J2KN features a handheld wireless remote control with full LCD display. The remote will operate up to 300 feet away, allows the operator to monitor and control all functions of the analyzer. The J2KN also includes an advanced sample conditioning system featuring a Peltier gas cooler & automatic moisture removal system. When used with the optional heated sample line, the J2KN meets current EPA protocols for compliance level portable analyzers. |
Instrument price includes:
Analyzer with sensors, handheld remote control, magnetic holster for remote, 15 foot sample line, 1 foot pistol grip probe, gas and ambient temperature measurement, stack pressure/draft, on-board impact printer with 2 rolls of printer paper, 1 package of particulate filters, 1 spare NOx/SO2 filter media cartridge, a protective case, and operation manual. Automatic CO over-range protection, Sensor Temperature Monitoring and Internal Temperature Compensation over the full operational range (20° - 105° F), plus CO2, Efficiency, Excess Air calculations and Data interface. |
Sensor Ranges: O2 (0.00 -21.0%), CO low (0-4,000 ppm), CO high (0-40,000 ppm), NO (0-4,000 ppm), NO2 (0-500 ppm), LOW NOX (0-400 ppm NO & 0-100 ppm NO2), SO2 (0-5,000 ppm), Combustibles (0-6.00%) |
|