ECOM America, Ltd.
1628 Oakbrook Drive
Gainesville, GA 30507

Toll Free 877.326.6411
TEL. 770.532.3280
FAX 770.532.3620

 


ECOM EN2

just ENough

BROCHURE

+ + + + +

Standard Features

The ECOM EN2 package includes:

  • Analyzer with up to 4 EC sensors for measurement of O2, CO, NO, and NO2
  • CO2, Efficiency, Losses, Excess Air, & Oxygen correction calculations
  • Internal pump
  • Sample line (15’) with Probe (10”)
  • Backlit LCD Display
  • Ambient, Flue Gas, Sensor Temperature Measurement
  • Thermo-electric Gas Cooler & Moisture Trap
  • On-board Flowmeter
  • On-board Fast Thermal Printer
  • Automatic CO Over-range Protection
  • Spare Consumables (filters, printer paper, etc.)
  • Data Processing Software with Bluetooth Option
  • Operation Manual
  • Protective Storage Case
  • ECOM EN2

    The ECOM EN2 is a compact portable combustion analyzer, offering features found on larger, more expensive units. Housed in a rugged aluminum frame and hard-side case, the EN2 measures up to 4 gases, from O2, CO, NO, NO2, plus probes for temperature and stack draft / pressure. The EN2 Also calculates CO2, efficiency and excess air. A strong, internal pump and peltier gas cooler with automatic condensate drain ensures proper sample conditioning, leading to better accuracy and longer sensor life. An on board printer, SD Memory Card and wireless Bluetooth are standard features. Common applications for the EN2 include set-up, maintenance and emission monitoring of natural gas, diesel, and oil fired boilers, burners, and reciprocating engines. The compact size, simple operation, and long battery life (6-8 hours) make the EN2 a perfect tool for field technicians.

    • TECHNICAL SPECS
    • close tab
    MEASUREMENT (KEY) RANGE ACCURACY RESOLUTION SENSOR LIFE SENSOR TYPE
    Oxygen (O) 0-21% ± 2% Measured 0.1% vol. 2 Years Electrochemical
    Carbon Monoxide (C) 0-4,000 ppm ± 2% Measured 1 ppm 3 Years Electrochemical
    Carbon Monoxide (V) 0-40,000 ppm ± 2% Measured 1 ppm 3 Years Electrochemical
    Nitric Oxide (N) 0-4,000 ppm ± 2% Measured 1 ppm 3 Years Electrochemical
    Nitrogen Dioxide (X) 0-500 ppm ± 2% Measured 1 ppm 3 Years Electrochemical
    Gas Temperature 32-1800 F ± 2% Measured 1 deg F 10 Years NiCrNi
    Ambient Temperature 0-250 F ± 2% Measured 1 deg F 10 Years Semi-Conductor
    Draft / Pressure ± 40" H2o ± 2% Measured 0.1% H2O 10 Years DMS
    O2 Correction 0-20% Oxygen
    Carbon Dioxide (CO2) 0-CO2 max of fuel Calculated      
    Efficiency 0-99.9% Calculated      
    Exxess Air (Lambda) 1- Infinity Calculated      
               
    *ACCURACY: When calibrated prior to use per ECOM America, Ltd. specifications.
     
    PHYSICAL Instrument: 3” x 10” x 4”
    Probe: 10” Length x 3/8” OD Inconel w/ Pistol Grip Handle*
    Sample Line: 15’ high-temp flex hose w/thermocouple wire*
    Weight: 1 lb.
     
    ELECTRICAL Batteries: 6-8 hour battery life, 6V lead-acid
    Pump: Flow rate of 1.5+ lpm
    Display: Backlit, adjustable contrast & zoom, displays all
    parameters simultaneously.
     
    OPERATING TEMPERATURE Core temperature of the instrument is monitored continuously.
    Internal Temperature Compensation software assures accurate
    sensor response over the range of 20°F to 104°F.
     
               
    *Optional probe & sample line lengths are available.