- TECHNICAL SPECS
- PARTS
- close tabs
| MEASUREMENT (KEY) |
RANGE |
ACCURACY |
RESOLUTION |
SENSOR LIFE |
SENSOR TYPE |
| Oxygen (O) |
0-21% vol. |
± 2% Reading |
0.1% vol. |
2 Years |
Electrochemical |
| Carbon Monoxide (C) |
0-4,000 ppm |
± 2% Reading |
1 ppm |
3 Years |
Electrochemical |
| Carbon Monoxide (V) |
0-40,000 ppm |
± 2% Reading |
5 ppm |
3 Years |
Electrochemical |
| Nitric Oxide (N) |
0-4,000 ppm |
± 2% Reading |
1 ppm |
3 Years |
Electrochemical |
| Nitric Dioxide (X) |
0-500 ppm |
± 2% Reading |
1 ppm |
3 Years |
Electrochemical |
| Sulfur Dioxide (S) |
0-5,000 ppm |
± 2% Reading |
1 ppm |
3 Years |
Electrochemical |
| Combusitbles (H) |
0-6% vol. |
± 2% Reading |
0.01% |
5 Years |
Pellister |
| Ambient Temperature |
0-250° F |
± 3° F |
1° F |
10 Years |
IC Sensor |
| Stack Temperature |
32.0-1,800° F |
± 3° F |
1° F |
10 Years |
Ni/CrNi/T/C |
| Stack Draft |
0-40.00" H2O |
± 2% Reading |
0.01" H2O |
10 Years |
Piezoresistive |
| Efficiency |
0-100% |
|
1% |
|
Calculated |
| Carbon Dioxide (CO2) |
0-CO2 max |
|
0.1% |
|
Calculated |
| Lambda |
0-50% |
|
0.01% |
|
Calculated |
| Losses |
0-100% |
|
1% |
|
Calculated |
| O2 Correction |
0-20.0% vol. |
|
0.1% |
|
Calculated |
| |
|
|
|
|
|
| |
|
|
|
|
|
| *ACCURACY: When calibrated prior to use per ECOM America, Ltd. specifications. |
| |
| PHYSICAL |
Instrument: 19” x 16” x 6.5” Aluminum Carry Case
Probe: 13” Length x 3/8” OD Inconel w/ Pistol Grip Handle*
Sample Line: 15’ high-temp flex hose w/thermocouple wire*
Weight: 28 lb. |
 |
| |
| ELECTRICAL |
AC: 110V 60Hz / 220V 50Hz (User selectable)
Batteries: Lead-acid rechargeable, life of 2.0-3.0 hrs.
Pump: Flow rate of 2.5 lpm
Display: Backlit, adjustable contrast & zoom, displays all
parameters simultaneously. |
 |
| |
| OPERATING TEMPERATURE |
Core temperature of the instrument is monitored continuously.
Internal Temperature Compensation software assures accurate
sensor response over the range of 20°F to 104°F. |
 |
| |
| |
|
|
|
|
|
| *Optional probe & sample line lengths are available. |
| |
|
|
|
|
|
| ECOM AC 4-7 Gas Analyzer |
Description |
ECOM Part# |
| AC Configurations |
|
|
 |
ECOM AC 4 GAS ANALYZER (OCNS) O2, CO (low), NO, SO2 |
RBR 69297 |
| ECOM AC 4 GAS ANALYZER (OCNX) O2, CO (low), NO, NO2 |
RBR 69298 |
| ECOM AC 5 GAS ANALYZER (OCNXS)O2, CO (low), NO, NO2, SO2 |
RBR 69199 |
| ECOM AC 5 GAS ANALYZER (OCVNX)O2, CO (low), CO (high), NO, NO2 |
RBR 69201 |
| |
AC 5 GAS ANALYZER (OCVNS)O2, CO (low), CO (high), NO, SO2 |
RBR 69202 |
| |
ECOM AC 5 GAS ANALYZER (OCNXH) O2, CO (low), NO, NO2, Combustibles |
RBR 69203 |
| |
ECOM AC 5 GAS ANALYZER(OCVNH) O2, CO (low), CO (high), NO, Combustibles |
RBR 69204 |
| |
ECOM AC 5 GAS ANALYZER (OCNSH) O2, CO (low), NO, SO2, Combustibles |
RBR 69205 |
| |
ECOM AC 6-gas analyzer (OCNXSH) O2, CO (low), NO, NO2, SO2, Combustibles |
RBR 69210 |
| |
ECOM AC 6-gas analyzer (OCVNXH) O2, CO (low), CO (high), NO, NO2, Combustibles |
RBR 69211 |
| |
ECOM AC 6-gas analyzer (OCVNXS) O2, CO (low), CO (high), NO, NO2, SO2 |
RBR 69212 |
| |
ECOM AC 7-gas analyzer (OCVNXSH) O2, CO (low), CO (high), NO, NO2, SO2, Combustibles |
RBR 69214 |
| Accessories & Options |
|
|
| |
| ADVANCED DAS 2.0 / USB - SOFTWARE - includes installation of hardware (USB Board & Electronic flowmeter), CD-ROM, 15' USB cable, and User Manual. |
|
PRT 90004 |
 |
Transport Case w/ wheels & telescoping handle |
PRT W827BL |
| Consumables |
|
|
 |
Impact Printer Ribbon |
RBR 69519 |
 |
Printer Paper for Impact Printer (pack of 5) |
PRT 79285 |
 |
NOx / SO2 Filter media (1 lb) |
NOXSOX 79275 |
 |
Heavy Duty In-line Filters (package of 5) |
PRT 79278 |
 |
Standard AC In-line Filters each |
PRT71185 |
 |
Particulate Filters (package of 10) |
FILTER75316 |
| SPARE PARTS |
|
|
 |
Water Trap Assembly w/ flowmeter |
RBR71263 |
 |
Flowmeter (small) |
FLOWMTR79282 |
 |
5 Foot Pistol Grip Probe (Standard) |
RBR 71270 |
 |
3 Foot Pistol Grip Probe (Standard) |
RBR 71271 |
 |
1 Foot Pistol Grip Probe (complete) |
RBR 71282 |
 |
1 Foot probe pipe |
RBR 71265 |
 |
Pistol Grip |
RBR 71280 |
 |
Probe Cone |
RBR 71297 |
 |
Pistol grips L&R (for old style probe grip) |
RBR 79328 |
 |
15 Foot Sample Line (Standard) |
RBR71277 |
 |
30 Foot Sample Line (Standard) |
RBR71279 |
 |
T-GAS dummy Thermocouple |
CONNECT70280 |
 |
Draft Connector Fitting (3 notch) |
CONNECT71301 |
 |
Gas Connector Fitting (2 notch) 8mm |
CONNECT71302 |
 |
O-ring for Draft Inlet (1.75x4) 7mm |
ORING71308 |
 |
O-ring for Gas Inlet (1.75x5) |
ORING71309 |
 |
Water Trap Bowl |
RBR 75325 |
 |
NOx / SOx Bead Tube |
RBR 71286 |
 |
AC Battery |
PRT 79288 |
 |
ON/OFF SWITCH |
RBR71180 |
 |
Switch Cover |
MISCSWCHCVR |
 |
Wireless Temperature Sensor |
MISC/PTC |
 |
MAIN PUMP |
PRT 70281 |
 |
Probe Calibration Attachment |
PROBE CAL ASSY |
| |
ECOM AC SERIAL NO. 9418 & UP USE SERIES 5 SENSORS!! Refer to A-PLUS price page for Series 5 sensor info |
| SENSORS |
|
|
 |
Oxygen (O2) |
RBR 75299 |
 |
Series 5 Oxygen Sensor Adapter
(used to replace 75300 w/ 75299) |
S5-O2 Modkit |
 |
Carbon Monoxide (low CO) |
RBR75292 |
 |
Sulfur Dioxide (SO2) |
RBR75301 |
 |
Nitric Oxide (NO) |
RBR75298 |
 |
Nitrogen Dioxide (NO2) |
RBR75296 |
 |
Carbon Monoxide (high CO) |
RBR 75293 |
 |
Combustible |
RBR 75313 |
| NOTES: |
| Please note: The combustible sensor, either Catalytic Pellistor or Infrared type must be serviced by ECOM factory personnel. |
| |
ECOM AC 4-7 Gas Emission Analyzer
The ECOM AC, fitted with 4, 5, 6, or 7 gas sensors, features gas and ambient
temperature measurement, stack pressure/draft measurement, on-board impact printer,
large LCD screen with zoom capability, auto-draining water trap with particulate filter,
in-line flowmeter, automatic CO over-range protection, Sensor Temperature Monitoring
and Internal Temperature Compensation over the full operational range (20° to 105° F),
RS232 interface, auto diagnostics, plus CO2, Efficiency, and Excess Air calculations. |
| |
Instrument price includes:
Analyzer with 15 foot sample line, 1 foot pistol grip probe, 2 rolls of printer paper, 1
package of smoke test paper and smoke test comparison chart, 1 package of particulate
filters, 1 package of NOx/SO2 filter media, a shoulder strap, and operation manual. |
| |
| Sensor Ranges: O2 (0.00 -21.0%), CO low (0-4,000 ppm), CO high (0-40,000 ppm), NO (0-4,000 ppm), NO2 (0-500 ppm), SO2 (0-5,000 ppm), Combustibles (0-6.00%) |
|