ECOM America, Ltd.
1628 Oakbrook Drive
Gainesville, GA 30507

Toll Free 877.326.6411
TEL. 770.532.3280
FAX 770.532.3620



 

 

About ECOM



Heated Sample Lines:

A custom length, self-regulating heated line is now available for use with the J2KN-IND, and VETS models. This line operates on 110 VAC, and has internal temperature controls to maintain the gas temperature above the dew point, eliminating condensation in the sample line.

Thermoelectric Peltier Cooler:

After travelling through the heated line, the sample gas enters the temperature controlled cooler, (maintained at 40 - 45 deg. F), where the moisture in the gas quickly condenses and is trapped in the water trap bowl.

Flow Meter:

Adjustable flow meters are now installed in-line, so operators are assured consistent flow of gas between calibrations and testing.
Pressure Control is regulated by ECOM's patented internal gas manifold system. All ECOM analyzers use a proprietary sensor manifold and pressure control device to deliver a precise sample of gas to each individual sensor.

Peristaltic Pump:

Automatically removes condensate from the water trap, minimizing the sample gas / moisture contact. Because the sample gas is properly conditioned and controlled prior to introduction to the sensors, the typical life of the sensors in ECOM analyzers is usually much longer, calibration stability much better, and sensor stability more consistent, than that of our competitors, resulting in lower lifetime maintenance costs.

ECOM America Ltd., the leader in portable emission / combustion analyzers manufactures models for many applications. From single gas Oxygen and Carbon Monoxide analyzers for flue gas testing to multi-gas analyzers measuring Oxygen, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide, Sulfur Dioxide, & Hydrocarbons offered in several configurations, we have instruments for most combustion applications. Several models are approved and recognized by Regional, State, and Federal Environmental and Air Quality Regulatory Agencies.

Proper Sample Conditioning is an important function of portable electrochemical sensor based analyzers. What truly sets ECOM analyzers apart from our competitors is the importance we have placed on sample conditioning and gas delivery techniques. Ensuring a consistently cool and dry gas sample to the sensors is crucial to long term reliability and accuracy of the analyzer. Our maintenance analyzers incorporate a high flow pump and radiated gas cooler / moisture trap. The moisture collects in a condensate bowl, and can be automatically or manually drained, depending on the model. Our compliance level models offer sample conditioning features not found on any other brand of portable emission analyzers available today. Along with high flow pumps, recent modifications and options continue to assure accurate and reliable emission testing data.


 

Our Compact, Handheld ECOM CN, is one of our popular portable emission analyzers

Other unique features of ECOM analyzers:

  • Electronic Temperature Compensation over the full operating range
  • Thermoelectric gas cooler and automatic moisture removal
  • Anti cross- interference software
  • Large Zoom display w/ Contrast control
  • Automatic CO over-range protection
  • Automatic switching of CO measurement ranges
  • Pressure Transducer for draft & backpressure measurement
  • Convenient NOx calculation displayed
  • Programmable Oxygen correction
  • Programmable setting for PPM, #/mBtu, mg/m3
  • Automatic purge prior to shutdown
  • Windows based Data Acquisition Software with real time display of measured parmaters and mass emissions (g/bhp, lbs/hr, tons/yr, lbs/mmBtu) using EPA Method 19. Follows current protocols for error proof report generation.
  •  

above: ECOM CN - Our handheld analyzer

 

ECOM CN

Compact, yet full featured, analyzer for any combustion applications such as boiler/burner set-up as well as engine analysis. O2,CO, Temperature, plus CO2, Efficiency, Excess Air and Oxygen Correction calculations.    
   

ECOM CL

The ECOM-CL is an easy to use gas analyzer designed for basic combustion monitoring in a variety of applications. The CL is fitted with up to 3 gas sensors, measuring O2, CO & NO, plus Stack and Ambient Temperatures, and Stack Pressure & Draft. The CL also calculates CO2, Efficiency, Losses, Excess Air and Oxygen correction 0-20%.


ECOM EN2

The ECOM EN2 is a compact portable combustion analyzer, offering features found on larger, more expensive units. Housed in a rugged aluminum frame and hard-side case, the EN2 measures up to 4 gases, from O2, CO, NO, NO2, plus probes for temperature and stack draft / pressure.
   

ECOM J2KN

Up to 5 gas analyzer, with wireless remote control & display, plus wireless data transmission using ECOM's Advanced DAS software. Features high flow pump, peltier cooler and optioanl heated sample line.  EPA Compliance Level Analyzer. Available with standard NOX or LOW NOX sensor range.    
   

ECOM J2KN-Industrial

Up to 5 gas analyzer, with wireless remote control & display, plus wireless data transmission using ECOM's Advanced DAS software. Features high flow pump, peltier cooler and optioanl heated sample line.  EPA Compliance Level Analyzer. Available with standard NOX or LOW NOX sensor range.


   

Calibration Gas:

Calibration is the single most important tool for maintaining the integrity of electrochemical sensors used in portable emission analyzers. ECOM offers a wide range of calibration gas concentrations suitable for emission testing and protocols